Parameter | 2C-3p | 3C-5p | 3C-5p | 3C-4p with k4 = 0 | Patlak-2p | Logan-2p |
---|---|---|---|---|---|---|
Metabolite correction | No | No | Yes | Yes | No | No |
k1 | 0.347 ± 0.399 | 0.271 ± 0.259 | 0.225 ± 0.179 | 0.206 ± 0.178 | ||
k2 | 0.219 ± 0.188 | 0.205 ± 0.134 | 0.169 ± 0.077 | 0.129 ± 0.073 | 0.143 ± 0.495 | |
k3 | 0.003 ± 0.004 | 0.031 ± 0.019 | 0.014 ± 0.005 | |||
k4 | 0.011 ± 0.025 | 0.016 ± 0.011 | ||||
K | 0.003 ± 0.004 | 0.028 ± 0.016 | 0.017 ± 0.007 | 0.001 ± 0.006 | ||
Vb | 0.03 ± 0.02 | 0.15 ± 0.10 | 0.18 ± 0.11 | 0.18 ± 0.11 | ||
Ved | 1.44 ± 0.56 | 1.23 ± 0.52 | 1.27 ± 0.58 | 1.52 ± 0.65 | 2.10 ± 0.89 | 1.53 ± 0.57 |
WRSS | 2,370 ± 3,372 | 1,632 ± 3,512 | 470 ± 685 | 903 ± 1,657 | ||
n (P < 0.05) | Reference | 22 | 48 | 33 |
↵* Estimates of fitted parameters k1–k4, influx rate constant K, blood volume fraction in tissue (Vb), and equilibrium distribution volume (Ved) were determined. Results are expressed as mean ± SD for 61 malignant tumors in 35 patients. Same model structures and corrections as those described in Table 1 were tested. See Table 1 for definitions of abbreviations as well.