Diagnostic Accuracy of 18F-FDOPA PET at Various Thresholds for Ratios of Tumor Uptake to Normal Tissue Uptake in Group 1 and Group 2 Patients
Threshold for ratio of tumor uptake to normal tissue uptake | Parameter (%) | Group1 patients (n = 30) | Group2 patients (n = 51) | Combining 2 groups (n = 81) |
---|---|---|---|---|
T/S > 0.75 | Sensitivity | 100 | 97 | 98 |
Specificity | 86 | 86 | 86 | |
Accuracy | 97 | 94 | 95 | |
PPV | 96 | 95 | 95 | |
NPV | 100 | 92 | 95 | |
T/S > 1.0 | Sensitivity | 96 | 86 | 92 |
Specificity | 100 | 93 | 95 | |
Accuracy | 97 | 88 | 93 | |
PPV | 100 | 94 | 98 | |
NPV | 88 | 75 | 80 | |
T/N > 1.3 | Sensitivity | 96 | 95 | 95 |
Specificity | 86 | 86 | 86 | |
Accuracy | 93 | 94 | 93 | |
PPV | 96 | 95 | 95 | |
NPV | 86 | 92 | 86 | |
T/W > 1.6 | Sensitivity | 96 | 92 | 93 |
Specificity | 86 | 86 | 86 | |
Accuracy | 93 | 84 | 91 | |
PPV | 96 | 87 | 95 | |
NPV | 86 | 75 | 82 |