TABLE 1

Percentage Injected Dose in Rats of 99mTc(CO)3(meso-LAN) and 99mTc(CO)3(dd,ll-LAN) Compared with 131I-OIH in Blood, Urine, and Selected Organs at 10 and 60 Minutes (n = 5)

BloodKidneysUrineLiverBowel
Isomer99mTc131I-OIH99mTc131I-OIH99mTc131I-OIH99mTc/131I-OIH ratio99mTc131I-OIH99mTc131I-OIH
meso-LAN
 10 min4.1 ± 0.43.3 ± 0.56.5 ± 2.84.9 ± 3.541.0 ± 7.359.9 ± 11.569 ± 64.2 ± 0.62.0 ± 0.21.2 ± 0.31.0 ± 0.2
 60 min0.6 ± 0.10.5 ± 0.11.2 ± 0.30.7 ± 0.377.9 ± 3.287.5 ± 8.289 ± 61.2 ± 0.50.8 ± 0.51.7 ± 0.10.9 ± 0.2
dd,ll-LAN
 10 min5.7 ± 0.74.0 ± 0.69.5 ± 0.94.6 ± 1.033.4 ± 3.959.2 ± 3.656 ± 43.9 ± 0.52.3 ± 0.21.7 ± 0.41.1 ± 0.2
 60 min0.7 ± 0.20.4 ± 0.11.2 ± 0.30.3 ± 0.176.4 ± 7.288.0 ± 7.887 ± 40.8 ± 0.30.5 ± 0.34.6 ± 0.70.9 ± 0.1
  • Data are mean ± SD.