TABLE 7

Detection of Bone Metastases on Planar BS and on Multi-FOV SPECT in 23 Patients with Metastatic Bone Involvement on 18F-Fluoride PET/CT: Patient-Based and Lesion-Based Analysis*

Patient no.18F-Fluoride PET/CT (no. of metastases)Planar BS imagesMulti-FOV SPECT images
Final diagnosisNo. of metastasesFinal diagnosisNo. of metastases
1NumerousTrue positiveNumerousTrue positiveNumerous
2NumerousTrue positiveNumerousTrue positiveNumerous
3NumerousTrue positiveNumerousTrue-positiveNumerous
45True positive4True positive5
56True positive4True positive4
63True positive1True positive2
74True positive2True positive3
84True positive1True positive2
95True positive3NA
104True positive3NA
113True positive2NA
122True positive2NA
132True positive1NA
142False negativeTrue positive2
154False negativeTrue positive4
162False negativeTrue positive2
171False negativeTrue positive1
181False negativeFalse negative
193False negativeNA
203False negativeNA
211False negativeNA
221False negativeNA
231False negativeNA
  • * Equivocal findings were considered suggestive of a bone metastasis on the 3 modalities.

  • Final diagnosis regarding the presence of bone metastases.

  • Multi-FOV SPECT was not available in these patients.