TABLE 2

Extraction Efficiency and Elution Efficiency Data and HPLC Analysis of Soluble Fraction of Tissue Samples at 60 Minutes After Injection

FractionBloodUrineLiverKidneyU87MG
Extraction efficiency (%)
Unsoluble fraction*6.9ND12.616.521.7
Soluble fraction93.1ND87.483.578.3
Elution efficiency (%)
Nonretained fraction2.10.237.114.515.2
Wash water§0.60.73.01.63.0
Acetonitrile eluent97.299.159.983.881.8
HPLC analysis (%)
Intact tracer90.695.593.587.879.9
  • * Amount of activity that was retained in pellets.

  • Amount of activity that was extracted to PBS solution.

  • Amount of activity that could not be trapped on C18 cartridge.

  • § Amount of activity that was eluted from C18 cartridge using 2 mL water.

  • Amount of activity that was eluted from C18 cartridge using 2 mL acetonitrile with 0.1% TFA.

  • ND = not determined.