TABLE 1

Important Radionuclides in RDDs, the Source, and Maximum Radioactivity for the Source

Maximum radioactivity for source
RadionuclideSourceBecquerelsCuries
60CoMedical therapeutics, industrial radiography, and food irradiation3.7 × 1015–2.96 × 1017100,000–8,000,000
137CsMedical diagnostics and therapeutics, blood irradiation to kill antibodies before transfusion, industrial radiography, and food irradiation3.7 × 1014–9.25 × 101510,000–250,000
192IrMedical therapeutics and industrial radiography3.7 × 10131,000
241AmIndustrial radiography7.4 × 101120
  • Data are from (1114).