TdR | FLT | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Tissue | Region | Mean | Min | Max | n | Mean | Min | Max | n | % Δ |
Transport (K1) | ||||||||||
Tumor | NCE | 0.018 | 0.005 | 0.028 | 13 | 0.005 | 0.003 | 0.007 | 3 | −72 |
CE | 0.057 | 0.036 | 0.082 | 6 | 0.053 | 0.015 | 0.126 | 9 | −7 | |
High | 0.052 | 0.021 | 0.082 | 7 | 0.052 | 0.005 | 0.126 | 9 | 3 | |
Low | 0.018 | 0.005 | 0.028 | 12 | 0.008 | 0.003 | 0.015 | 3 | −8 | |
C/L brain | 0.020 | 0.007 | 0.051 | 24 | 0.004 | 0.003 | 0.006 | 12 | −63 | |
Metabolic flux (KTdR or KFLT) | ||||||||||
Tumor | NCE | 0.011 | 0.005 | 0.016 | 13 | 0.001 | 0.001 | 0.002 | 3 | −88 |
CE | 0.041 | 0.019 | 0.059 | 6 | 0.018 | 0.008 | 0.033 | 9 | −55 | |
High | 0.030 | 0.016 | 0.059 | 7 | 0.018 | 0.002 | 0.033 | 9 | −39 | |
Low | 0.011 | 0.005 | 0.016 | 12 | 0.003 | 0.001 | 0.008 | 3 | −49 | |
C/L brain | 0.011 | 0.001 | 0.022 | 24 | 0.002 | 0.001 | 0.003 | 12 | −82 | |
Mean flux ratio for FLT/TdR in C/L brain | 0.23 | |||||||||
Mean flux ratio for FLT/TdR in high-grade gliomas | 0.56 |
NCE = noncontrast-enhancing tumor; CE = contrast-enhancing tumor with MRI T1+Gd imaging; High = glioma grades III and IV; Low = glioma grade II; % Δ = percent difference in mean parameter value of TdR vs. FLT.