TABLE 7

Comparison Between TdR Parameters Reported Previously and FLT in This Study

TdRFLT
TissueRegionMeanMinMaxnMeanMinMaxn% Δ
Transport (K1)
TumorNCE0.0180.0050.028130.0050.0030.0073−72
CE0.0570.0360.08260.0530.0150.1269−7
High0.0520.0210.08270.0520.0050.12693
Low0.0180.0050.028120.0080.0030.0153−8
C/L brain0.0200.0070.051240.0040.0030.00612−63
Metabolic flux (KTdR or KFLT)
TumorNCE0.0110.0050.016130.0010.0010.0023−88
CE0.0410.0190.05960.0180.0080.0339−55
High0.0300.0160.05970.0180.0020.0339−39
Low0.0110.0050.016120.0030.0010.0083−49
C/L brain0.0110.0010.022240.0020.0010.00312−82
Mean flux ratio for FLT/TdR in C/L brain0.23
Mean flux ratio for FLT/TdR in high-grade gliomas0.56
  • NCE = noncontrast-enhancing tumor; CE = contrast-enhancing tumor with MRI T1+Gd imaging; High = glioma grades III and IV; Low = glioma grade II; % Δ = percent difference in mean parameter value of TdR vs. FLT.