TABLE 5

Radiation Dose per Injected Activity (cGy/37 MBq) Based on MIRD Reference Man’s Mass and Patient-Specific Organ Mass

Patient no.cGy/37 MBq (or rad/mCi)
BodyLiverSpleenKidneysLungs*Marrow, SpTumor, Sp
RefSpRefSpRefSpRefSpRefSp
10.650.551.842.001.342.5610.058.350.260.090.348.9
20.510.320.800.631.781.509.414.900.277.9, 10.4
30.820.788.886.897.674.4612.0310.080.3094.3, 121.6
40.500.563.114.461.901.715.936.010.590.370.21
50.840.699.874.635.822.7711.976.530.740.440.13
60.640.645.786.032.412.878.387.080.1511.7, 34.2
70.570.374.742.6712.102.1714.9811.250.2420.0
80.450.392.201.182.490.587.945.620.126.4, 4.2, 6.6
90.590.4511.115.273.472.255.363.360.2121.0, 33.8
  • * Lungs were not visualized above body background. Lungs of 3 patients were randomly selected to illustrate that lung doses were ≤ body doses.

  • Normal liver excluding tumors.

  • Ref = MIRD Reference Man’s mass; Sp = patient-specific organ mass.