TABLE 2

Effect of Signal Intensities on Assessment of Left Ventricular Volumes and Ejection Fraction

SIEDV (mL)ESV (mL)EF (%)
25%110 ± 645 ± 660 ± 3*
75%111 ± 443 ± 362 ± 3
100%114 ± 342 ± 163 ± 1
  • * P = 0.01 vs. 100% SI.