TABLE 4

SUV, Patlak (mL/min/mL), and NLR (mL/min/mL) Values and Relative Change (%) Between 2 Scans for Normal Limb Bones Imaged Twice

Time (mo)LocationSUVChange (%)PatlakChange (%)NLRChange (%)
Scan 1Femur3.70.02030.0215
Scan 230Femur4.417.30.025623.40.027825.6
Scan 1Femur1.40.00530.0053
Scan 26Femur0.9−43.50.0042−22.60.0050−5.1
Scan 1Femur2.80.01560.0155
Scan 25Femur2.6−7.40.0156−0.50.0148−4.9
Scan 1Femur0.80.00500.0053
Scan 27Femur0.800.0048−5.10.0049−7.6
Scan 1Humerus1.30.00480.0046
Scan 27Humerus1−26.10.0047−1.30.00460.0
Scan 1Humerus0.60.00390.0038
Scan 25Humerus0.4−40.00.0038−2.60.0035−8.2
Scan 1Humerus10.00660.0077
Scan 26Humerus0.9−10.50.0058−11.90.0059−26.8
Scan 1Tibia1.10.00630.0072
Scan 25Tibia1.848.30.00709.80.0064−11.2
Scan 1Fibula0.80.00380.0034
Scan 25Fibula0.800.004414.00.00378.5
Mean−6.9*0.3*−3.3*
SD28.613.814.4
  • * Not significantly different (ANOVA; P > 0.05).

  • Time = time difference between 2 scans.

    Significant correlations were found between SUV and Patlak (r = 0.68; P < 0.5) and Patlak and NLR (r = 0.70; P < 0.5). SUV and NLR were not significantly correlated (r = 0.17; P > 0.5).