TABLE 2

Biodistribution in Tumored Mice (Study 1)

OrganStudy (111In-antibody, 99mTc-polymer)99mTc-polymer onlyP value*
111In99mTc [1]99mTc [2][1] vs. [2]
Liver9.20 ± 0.7429.1 ± 1.729.4 ± 1.00.745
Heart1.36 ± 0.330.66 ± 0.040.77 ± 0.100.091
Kidney12.2 ± 0.625.28 ± 0.845.36 ± 0.790.888
Lung2.12 ± 0.100.43 ± 0.090.40 ± 0.060.646
Spleen3.96 ± 0.6312.7 ± 2.011.8 ± 0.980.419
Muscle0.68 ± 0.020.15 ± 0.040.16 ± 0.040.566
Tumor11.0 ± 0.571.17 ± 0.170.77 ± 0.100.002
Blood3.46 ± 0.400.32 ± 0.030.21 ± 0.040.004
  • Study animals received 111In-labeled antibody 48 h earlier. Control animals did not receive antibody and received only labeled polymer 18 h earlier.

  • * Student t test for significance, P < 0.05 (statistically significant values are underlined).

  • Data are expressed as average %ID/g ± SD; n = 8.