Values of Absorbed Dose to Testes and Effective Dose for 111ln Chloride Using Different Models of Biologic Clearance from Testis
Model | Testicular self-dose (mGy/MBq) | Total testicular absorbed dose (mGy/MBq) | Effective dose (mSv/MBq) |
---|---|---|---|
ICRP (17,30,31) | 0.015 | 0.053 | 0.21 |
This work | |||
Model I | 0.134 ± 0.013 | 0.172 ± 0.013 | 0.22 ± 0.001 |
Model II | 0.168 ± 0.017 | 0.206 ± 0.017 | 0.22 ± 0.002 |
Model III | 0.096 ± 0.014 | 0.135 ± 0.014 | 0.22 ± 0.001 |