TABLE 1

Patient Data

Patient no.SexFindingsPET effect
PETCTNeck sonography131I/123IPathology
LocalDistantLocalDistant
1MNegPosNAIndeterminateNegNDPosIndeterminate lung nodule shown to be positive on PET
2MNegPosNAPosNegNegPosMuch more extensive distant disease on PET
3aFNegPosNAPosNegNegPosConfirmed disease
3bFPosNegNANegPosNDND (F/U pos)Confirmed disease
4MNegPosNAPosPosNegND (F/U pos)Confirmed disease
5FNegPosNAPosNegNDND (F/U pos)Confirmed disease
6MNegPosNAPosNegNDPosConfirmed disease
7FNegNegNANegNegIndeterminateNegConfirmed disease
8MNegPosNDNDNegNegPosShowed unknown distant disease (pelvis)
9FNegNegNegNegPosNDPosPET falsely read as negative
10FPosPosNegNegNANDPosShowed unknown distant disease (mediastinum)
11MPosPosPosNegNegNDNeg (pleural fluid)Suspected metastatic disease from PET: treated
12aMPosPosPosIndeterminatePosNegPosIndeterminate lung nodules shown to be positive on PET
12bMPosNegNegIndeterminateIndeterminateNegPosActive local disease seen on PET only
  • Neg = negative result; Pos = positive result; ND = not done; F/U pos = follow-up considered active disease to be present.