Source Located in Renal Medulla of 15 Year Old
Targets | Photon absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 1.25E−01 | 2.62E−01 | 2.72E−01 | 1.69E−01 | 7.08E−02 | 3.98E−02 | 4.01E−02 | 4.10E−02 | 3.81E−02 | 3.45E−02 | 3.16E−02 | 2.28E−02 | |||||||||||
Medulla | 8.35E−01 | 5.84E−01 | 3.76E−01 | 1.62E−01 | 5.62E−02 | 3.24E−02 | 3.42E−02 | 3.59E−02 | 3.14E−02 | 2.69E−02 | 2.30E−02 | 1.38E−02 | |||||||||||
Pelvis | 2.15E−02 | 4.27E−02 | 3.80E−02 | 2.05E−02 | 7.72E−03 | 4.37E−03 | 4.43E−03 | 4.66E−03 | 4.23E−03 | 3.94E−03 | 3.56E−03 | 2.35E−03 | |||||||||||
Papillae | 1.28E−02 | 1.25E−02 | 9.54E−03 | 4.66E−03 | 1.70E−03 | 9.67E−04 | 9.89E−04 | 1.05E−03 | 9.42E−04 | 8.13E−04 | 7.28E−04 | 4.68E−04 | |||||||||||
Trunk | 6.00E−03 | 9.75E−02 | 2.83E−01 | 5.03E−01 | 4.79E−01 | 3.56E−01 | 3.25E−01 | 3.19E−01 | 3.01E−01 | 2.82E−01 | 2.66E−01 | 2.23E−01 |
Targets | Electron absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 0.00E+00 | 8.46E−05a | 1.77E−04 | 3.64E−04 | 8.72E−04 | 2.88E−03 | 9.74E−03 | 4.30E−02 | 1.15E−01 | 1.89E−01 | 2.48E−01 | 3.44E−01 | |||||||||||
Medulla | 1.00E+00 | 1.00E+00 | 1.00E+00 | 9.99E−01 | 9.99E−01 | 9.96E−01 | 9.86E−01 | 9.40E−01 | 8.46E−01 | 7.49E−01 | 6.67E−01 | 4.58E−01 | |||||||||||
Pelvis | 0.00E+00 | 1.41E−05c | 3.52E−05b | 5.53E−05a | 1.31E−04 | 4.73E−04 | 1.44E−03 | 5.96E−03 | 1.81E−02 | 3.52E−02 | 4.75E−02 | 5.33E−02 | |||||||||||
Papillae | 0.00E+00 | 1.69E−05c | 4.45E−05a | 8.52E−05a | 2.14E−04 | 7.42E−04 | 2.36E−03 | 9.23E−03 | 1.57E−02 | 1.47E−02 | 1.36E−02 | 1.23E−02 | |||||||||||
Trunk | 0.00E+00 | 0.00E+00 | 8.45E−07c | 5.91E−07c | 1.53E−05b | 7.30E−05 | 2.42E−04 | 7.44E−04 | 2.57E−03 | 7.80E−03 | 1.94E−02 | 1.23E−01 |