Targets | Photon absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 8.69E−01 | 6.64E−01 | 4.60E−01 | 2.19E−01 | 8.26E−02 | 4.73E−02 | 4.90E−02 | 5.10E−02 | 4.55E−02 | 3.94E−02 | 3.50E−02 | 2.26E−02 | |||||||||||
Medulla | 5.25E−02 | 8.81E−02 | 8.67E−02 | 5.36E−02 | 2.27E−02 | 1.29E−02 | 1.28E−02 | 1.32E−02 | 1.21E−02 | 1.11E−02 | 1.02E−02 | 7.32E−03 | |||||||||||
Pelvis | 2.98E−03 | 7.88E−03 | 9.64E−03 | 7.08E−03 | 3.29E−03 | 1.89E−03 | 1.86E−03 | 1.80E−03 | 1.73E−03 | 1.57E−03 | 1.40E−03 | 1.09E−03 | |||||||||||
Papillae | 2.53E−04a | 7.57E−04 | 1.30E−03 | 1.12E−03 | 5.71E−04 | 3.07E−04 | 2.96E−04 | 3.08E−04 | 2.61E−04 | 2.60E−04 | 2.31E−04 | 1.84E−04 | |||||||||||
Trunk | 7.49E−02 | 2.38E−01 | 4.15E−01 | 5.64E−01 | 4.93E−01 | 3.60E−01 | 3.33E−01 | 3.28E−01 | 3.10E−01 | 2.90E−01 | 2.72E−01 | 2.27E−01 |
Targets | Electron absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 1.00E+00 | 1.00E+00 | 1.00E+00 | 1.00E+00 | 9.99E−01 | 9.96E−01 | 9.87E−01 | 9.48E−01 | 8.74E−01 | 8.06E−01 | 7.45E−01 | 5.61E−01 | |||||||||||
Medulla | 0.00E+00 | 5.24E−05b | 1.14E−04a | 2.42E−04 | 5.99E−04 | 1.88E−03 | 6.12E−03 | 2.47E−02 | 5.45E−02 | 7.52E−02 | 8.91E−02 | 1.07E−01 | |||||||||||
Pelvis | 0.00E+00 | 4.10E−06c | 8.67E−06b | 2.17E−05b | 4.72E−05a | 1.67E−04 | 5.03E−04 | 1.57E−03 | 2.60E−03 | 3.32E−03 | 5.27E−03 | 1.15E−02 | |||||||||||
Papillae | 0.00E+00 | 9.96E−07c | 6.27E−06c | 1.13E−05c | 2.49E−05b | 6.30E−05a | 1.79E−04 | 2.56E−04 | 2.18E−04 | 2.74E−04 | 3.42E−04 | 9.90E−04 | |||||||||||
Trunk | 0.00E+00 | 3.07E−05b | 9.88E−05a | 2.05E−04 | 5.37E−04 | 1.83E−03 | 5.73E−03 | 2.47E−02 | 6.64E−02 | 1.12E−01 | 1.55E−01 | 3.10E−01 |