Source Located in Renal Cortex of 10 Year Old
Targets | Photon absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 8.58E−01 | 6.40E−01 | 4.36E−01 | 2.03E−01 | 7.41E−02 | 4.27E−02 | 4.46E−02 | 4.62E−02 | 4.12E−02 | 3.59E−02 | 3.12E−02 | 2.01E−02 | |||||||||||
Medulla | 5.71E−02 | 9.35E−02 | 8.88E−02 | 5.24E−02 | 2.14E−02 | 1.20E−02 | 1.21E−02 | 1.26E−02 | 1.18E−02 | 1.03E−02 | 9.52E−03 | 6.85E−03 | |||||||||||
Pelvis | 3.27E−03 | 8.59E−03 | 1.02E−02 | 7.10E−03 | 3.16E−03 | 1.75E−03 | 1.76E−03 | 1.79E−03 | 1.69E−03 | 1.50E−03 | 1.41E−03 | 1.04E−03 | |||||||||||
Papillae | 1.88E−04 | 7.49E−04 | 1.16E−03 | 9.26E−04 | 4.27E−04 | 2.29E−04 | 2.33E−04 | 2.27E−04 | 2.35E−04 | 1.89E−04 | 1.71E−04 | 1.50E−04 | |||||||||||
Trunk | 8.17E−02 | 2.52E−01 | 4.22E−01 | 5.41E−01 | 4.38E−01 | 3.02E−01 | 2.82E−01 | 2.81E−01 | 2.65E−01 | 2.47E−01 | 2.31E−01 | 1.90E−01 |
Targets | Electron absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 1.00E+00 | 1.00E+00 | 1.00E+00 | 9.99E−01 | 9.99E−01 | 9.96E−01 | 9.86E−01 | 9.43E−01 | 8.62E−01 | 7.89E−01 | 7.24E−01 | 5.31E−01 | |||||||||||
Medulla | 0.00E+00 | 5.99E−05c | 1.18E−04a | 2.52E−04 | 6.65E−04 | 2.09E−03 | 6.86E−03 | 2.71E−02 | 5.97E−02 | 8.17E−02 | 9.59E−02 | 1.13E−01 | |||||||||||
Pelvis | 0.00E+00 | 5.01E−06c | 8.00E−06c | 2.88E−05a | 5.70E−05a | 1.83E−04 | 5.40E−04 | 1.72E−03 | 2.90E−03 | 3.86E−03 | 6.13E−03 | 1.21E−02 | |||||||||||
Papillae | 0.00E+00 | 9.61E−07c | 0.00E+00 | 7.02E−06c | 1.62E−05c | 3.85E−05b | 9.66E−05 | 9.44E−05 | 1.44E−04 | 2.31E−04 | 3.00E−04 | 1.05E−03 | |||||||||||
Trunk | 0.00E+00 | 3.59E−05b | 1.02E−04 | 2.22E−04 | 5.95E−04 | 1.93E−03 | 6.31E−03 | 2.73E−02 | 7.26E−02 | 1.21E−01 | 1.69E−01 | 3.30E−01 |