Targets | Photon absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 1.03E−01 | 2.02E−01 | 2.10E−01 | 1.29E−01 | 5.21E−02 | 2.90E−02 | 2.93E−02 | 3.03E−02 | 2.80E−02 | 2.52E−02 | 2.33E−02 | 1.71E−02 | |||||||||||
Medulla | 1.08E−01 | 2.13E−01 | 1.85E−01 | 9.26E−02 | 3.36E−02 | 1.89E−02 | 1.97E−02 | 2.06E−02 | 1.93E−02 | 1.74E−02 | 1.57E−02 | 1.02E−02 | |||||||||||
Pelvis | 7.29E−01 | 4.19E−01 | 2.27E−01 | 8.09E−02 | 2.48E−02 | 1.45E−02 | 1.60E−02 | 1.68E−02 | 1.42E−02 | 1.12E−02 | 8.82E−03 | 4.16E−03 | |||||||||||
Papillae | 3.98E−02 | 3.48E−02 | 2.16E−02 | 8.19E−03 | 2.65E−03 | 1.49E−03 | 1.62E−03 | 1.72E−03 | 1.61E−03 | 1.37E−03 | 1.14E−03 | 5.62E−04 | |||||||||||
Trunk | 2.01E−02 | 1.30E−01 | 3.25E−01 | 4.98E−01 | 4.01E−01 | 2.65E−01 | 2.46E−01 | 2.45E−01 | 2.30E−01 | 2.14E−01 | 2.00E−01 | 1.64E−01 |
Targets | Electron absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 1.00E−06c | 9.50E−05a | 2.39E−04 | 4.52E−04 | 1.14E−03 | 3.93E−03 | 1.26E−02 | 4.77E−02 | 1.03E−01 | 1.43E−01 | 1.74E−01 | 2.71E−01 | |||||||||||
Medulla | 0.00E+00 | 4.95E−05a | 8.95E−05a | 1.59E−04 | 4.65E−04 | 1.57E−03 | 5.28E−03 | 2.78E−02 | 9.55E−02 | 1.71E−01 | 2.38E−01 | 2.73E−01 | |||||||||||
Pelvis | 1.00E+00 | 1.00E+00 | 1.00E+00 | 9.99E−01 | 9.98E−01 | 9.92E−01 | 9.72E−01 | 8.89E−01 | 7.35E−01 | 6.01E−01 | 4.90E−01 | 2.60E−01 | |||||||||||
Papillae | 0.00E+00 | 7.98E−05a | 1.22E−04 | 3.09E−04 | 7.31E−04 | 2.48E−03 | 7.99E−03 | 2.89E−02 | 4.75E−02 | 5.02E−02 | 4.74E−02 | 2.75E−02 | |||||||||||
Trunk | 0.00E+00 | 1.01E−05c | 1.90E−05b | 3.90E−05b | 1.25E−04 | 4.38E−04 | 1.41E−03 | 5.91E−03 | 1.66E−02 | 2.99E−02 | 4.53E−02 | 1.56E−01 |