Targets | Photon absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 1.64E−01 | 2.81E−01 | 2.45E−01 | 1.26E−01 | 4.61E−02 | 2.57E−02 | 2.71E−02 | 2.85E−02 | 2.64E−02 | 2.37E−02 | 2.14E−02 | 1.42E−02 | |||||||||||
Medulla | 7.76E−01 | 4.94E−01 | 2.93E−01 | 1.14E−01 | 3.68E−02 | 2.14E−02 | 2.32E−02 | 2.44E−02 | 2.12E−02 | 1.74E−02 | 1.46E−02 | 8.03E−03 | |||||||||||
Pelvis | 3.46E−02 | 4.82E−02 | 3.54E−02 | 1.56E−02 | 5.30E−03 | 3.01E−03 | 3.18E−03 | 3.42E−03 | 3.15E−03 | 2.80E−03 | 2.54E−03 | 1.41E−03 | |||||||||||
Papillae | 1.14E−02 | 9.91E−03 | 6.48E−03 | 2.76E−03 | 8.54E−04 | 5.10E−04 | 5.52E−04 | 5.84E−04 | 5.01E−04 | 4.39E−04 | 3.87E−04 | 2.05E−04 | |||||||||||
Trunk | 1.33E−02 | 1.58E−01 | 3.59E−01 | 4.79E−01 | 3.35E−01 | 2.08E−01 | 1.98E−01 | 2.01E−01 | 1.88E−01 | 1.75E−01 | 1.63E−01 | 1.32E−01 |
Targets | Electron absorbed fraction of energy Energy (MeV) | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.010 | 0.015 | 0.020 | 0.030 | 0.050 | 0.100 | 0.200 | 0.500 | 1.000 | 1.500 | 2.000 | 4.000 | ||||||||||||
Cortex | 0.00E+00 | 1.13E−04a | 2.27E−04 | 5.03E−04 | 1.35E−03 | 4.37E−03 | 1.41E−02 | 6.17E−02 | 1.61E−01 | 2.50E−01 | 3.10E−01 | 3.49E−01 | |||||||||||
Medulla | 1.00E+00 | 1.00E+00 | 1.00E+00 | 9.99E−01 | 9.98E−01 | 9.94E−01 | 9.80E−01 | 9.15E−01 | 7.84E−01 | 6.61E−01 | 5.68E−01 | 3.52E−01 | |||||||||||
Pelvis | 0.00E+00 | 2.02E−05b | 3.92E−05b | 8.41E−05a | 2.40E−04 | 7.61E−04 | 2.46E−03 | 1.13E−02 | 3.59E−02 | 5.63E−02 | 6.46E−02 | 4.98E−02 | |||||||||||
Papillae | 0.00E+00 | 2.76E−05c | 5.10E−05a | 9.58E−05a | 2.48E−04 | 8.28E−04 | 2.61E−03 | 9.76E−03 | 1.31E−02 | 1.22E−02 | 1.17E−02 | 8.64E−03 | |||||||||||
Trunk | 0.00E+00 | 0.00E+00 | 5.67E−07c | 2.90E−06c | 1.56E−05c | 6.48E−05 | 1.79E−04 | 5.32E−04 | 3.39E−03 | 1.52E−02 | 3.95E−02 | 2.22E−01 |