TABLE 1

Cellular S Values for 213Po

RC (μm)RN (μm)S(C ← C) (Gy/Bq/s)S(C ← CS) (Gy/Bq/s)S(N ← N) (Gy/Bq/s)S(N ← Cy) (Gy/Bq/s)S(N ← CS) (Gy/Bq/s)
321.95E−011.30E−014.37E−011.50E−019.74E−02
311.95E−011.30E−011.74E+001.97E−018.97E−02
431.10E−017.36E−021.95E−018.02E−025.70E−02
421.10E−017.36E−024.37E−019.66E−025.23E−02
547.05E−024.72E−021.10E−014.99E−023.76E−02
537.05E−024.72E−021.95E−015.73E−023.45E−02
527.05E−024.72E−024.37E−016.75E−023.29E−02
654.91E−023.29E−027.05E−023.41E−022.67E−02
644.91E−023.29E−021.10E−013.80E−022.46E−02
634.91E−023.29E−021.95E−014.32E−022.34E−02
763.62E−022.42E−024.91E−022.48E−022.01E−02
753.62E−022.42E−027.05E−022.71E−021.85E−02
743.62E−022.42E−021.10E−013.01E−021.76E−02
733.62E−022.42E−021.95E−013.38E−021.70E−02
872.77E−021.86E−023.62E−021.89E−021.56E−02
862.77E−021.86E−024.91E−022.03E−021.45E−02
852.77E−021.86E−027.05E−022.22E−021.38E−02
842.77E−021.86E−021.10E−012.45E−021.33E−02
982.20E−021.48E−022.77E−021.49E−021.25E−02
972.20E−021.48E−023.62E−021.58E−021.16E−02
962.20E−021.48E−024.91E−021.71E−021.11E−02
952.20E−021.48E−027.05E−021.86E−021.07E−02
1091.79E−021.21E−022.20E−021.21E−021.03E−02
1081.79E−021.21E−022.77E−021.27E−029.59E−03
1071.79E−021.21E−023.62E−021.35E−029.15E−03
1061.79E−021.21E−024.91E−021.46E−028.82E−03
1051.79E−021.21E−027.05E−021.57E−028.59E−03
  • RC = cellular radius; RN = nuclear radius; C = cell volume; CS = cell surface; N = nucleus; Cy = cytoplasm; S(X ← Y) = S factor for X target and Y source.