Effect of Ventricle Caudal Angulation and Respiratory Amplitude on Inferior-to-Anterior and Anterior-to-Lateral Wall Ratios
201Tl wall ratio | Amplitude (cm) | Angle | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
15° | 30° | 45° | ||||||||||
FBP | AC | FBP | AC | FBP | AC | |||||||
Inferior-to-anterior* | 0 | 0.97 ± 0.04† | 1.11 ± 0.07†‡ | 0.78 ± 0.04 | 1.05 ± 0.08 | 0.72 ± 0.10 | 0.98 ± 0.13 | |||||
1 | 0.94 ± 0.04† | 1.11 ± 0.04†‡ | 0.80 ± 0.03 | 1.07 ± 0.06‡ | 0.75 ± 0.11 | 0.92 ± 0.12 | ||||||
2 | 0.96 ± 0.07† | 1.22 ± 0.05†‡ | 0.80 ± 0.06 | 1.07 ± 0.04‡ | 0.69 ± 0.13 | 0.95 ± 0.16 | ||||||
Anterior-to-lateral§ | 0 | 1.00 ± 0.07¶ | 1.10 ± 0.07¶ | 1.14 ± 0.07¶ | 1.11 ± 0.05¶ | 1.05 ± 0.07¶ | 1.05 ± 0.06¶ | |||||
1 | 0.91 ± 0.08 | 0.88 ± 0.04 | 1.05 ± 0.07 | 1.01 ± 0.04 | 0.95 ± 0.07 | 0.92 ± 0.08 | ||||||
2 | 0.75 ± 0.05 | 0.74 ± 0.03 | 0.84 ± 0.06 | 0.78 ± 0.06 | 0.88 ± 0.06 | 0.80 ± 0.08 |
↵* All inferior-to-anterior FBP vs. AC pairs, P < 0.002.
↵† All inferior-to-anterior 15° vs. 45° pairs, P < 0.05.
↵‡ Inferior-to-anterior AC vs. unity, P < 0.05.
↵§ All anterior-to-lateral FBP vs. AC pairs, P = not significant.
↵¶ All anterior-to-lateral 0-cm vs. 2-cm pairs, P < 0.001.
Data are expressed as mean ± 1 SD. Cold liver and spleen inserts were present. Respiratory pattern was normal respiration.