TABLE 2

Scintigraphic Results of Pretherapy 99mTc-Sestamibi Study

Patient no.Uptake index, earlyUptake index, delayedWOR (%)Test result
10.921.0317Negative
21.410.8669Positive
32.171.8343Negative
40.631.0921Negative
51.060.7154Positive
61.620.6448Positive
71.881.4664Positive
82.260.8077Positive
92.822.4141Negative
101.702.5414Negative
111.090.5081Positive
121.410.3392Positive
131.431.0951Positive
141.730.9578Positive
151.371.1149Positive
161.041.4029Negative
172.161.4642Negative
180.480.5543Negative
193.632.1845Negative
202.271.1970Positive
211.271.1054Positive
224.854.8544Negative
231.741.0264Positive
241.772.0247Positive
254.853.7146Positive
261.301.0056Positive
272.382.4241Negative
283.812.6446Positive
292.073.5130Negative
304.493.0251Positive
  • Early uptake index = 99mTc-sestamibi uptake index in acquisition at 10 min; delayed uptake index = 99mTc-sestamibi uptake index in acquisition at 240 min; positive test result = WOR > 45%; negative test result = WOR ≤ 45%.