TABLE 4

Comparison of Detectability of Bone Metastases Between 99mTc-HMDP and 99mTc-MIBI Scans in Regions Other Than Femur and Humerus

Primary malignancyNo. of metastases99mTc-HMDP(+), 99mTc-MIBI(−)99mTc-HMDP(−), 99mTc-MIBI(+)99mTc-HMDP(+), 99mTc-MIBI(+)99mTc-HMDP(+)*99mTc-MIBI(+)*99mTc-HMDP vs. 99mTc-MIBI
Breast cancer4810132535 (72.9)38 (79.2)NS
Lung cancer391391730 (76.9)26 (66.7)NS
Prostate cancer27911726 (96.3)18 (66.7)P < 0.025
Myeloma19071212 (63.2)19 (100)P < 0.025
Hepatoma90188 (88.9)9 (100)NS
Gastric cancer17401317 (100)13 (76.5)NS
Bladder cancer15021313 (86.7)15 (100)NS
Renal cancer64026 (100)2 (33.3)NS
Colon cancer82068 (100)6 (75.0)NS
  • * Value in parentheses is percentage.

  • 99mTc-HMDP(+) = 99mTc-HMDP positive; 99mTc-HMDP(−) = 99mTc-HMDP negative; 99mTc-MIBI(+) = 99mTc-MIBI positive; 99mTc-MIBI(−) = 99mTc-MIBI negative; NS = not significant.