TABLE 2

MRI Variables in Segments from Healthy Volunteers and in Patient Segments With and Without 201TI Defects

VariableHealthy volunteers (n = 74)Patients
No 201TI defects (n = 67)201TI defects (n = 21)
Thickness (cm)0.99 ± 0.15*1.23 ± 0.33*0.88 ± 0.30
Curvature radii (cm)
 Circumferential3.2 ± 1.24.2 ± 1.73.3 ± 1.6
 Meridional20 ± 41*13 ± 216 ± 4
Diastolic wall tension index (N · m−1 · mm Hg−1)3.2 ± 1.2*3.3 ± 1.1*2.5 ± 1.0
Diastolic wall stress index (hN · m−2 · mm Hg−1)3.2 ± 1.62.8 ± 1.23.0 ± 1.4
  • * P < 0.05 for comparisons with segments that have 201TI SPECT defects.

  • Apical segments, which are not analyzed using meridional and circumferential curvature radii, are excluded.

  • End-diastolic wall tension and wall stress were calculated for standard value of 1 mm Hg of left ventricular hydrostatic pressure at end-diastole.