TABLE 3

Receptor Concentration Estimated Using Kinetics and Graphic Approaches on Data Obtained from the 8 Multiinjection Experiments

ParameterMultiinjection methodGraphic method
First estimation typeSecond estimation typeThird estimation type
Vascular fraction
 FV valueEstimated0.40.40.4
 Function usedBlood samplingBlood samplingBlood samplingPET measurement in cavity
Input function/corrections
 Protein binding22%
 μ (red cells)1.151.15
 Function usedPlasma samplingPlasma samplingBlood samplingPET measurement in cavity
Receptor concentration
 Experiment 117.515.815.716.0
 Experiment 211.611.210.910.7
 Experiment 311.511.611.511.5
 Experiment 48.89.69.69.7
 Experiment 517.417.418.217.6
 Experiment 612.115.414.112.9
 Experiment 710.013.211.512.3
 Experiment 812.915.214.114.5
 Mean12.713.713.213.1
 SD3.22.72.82.7
  • Table 1 shows doses used. Receptor concentration is in pmol/mL. Detailed results of multiinjection approach are given in Table 2.