Compartment | Approach | Half-life* | Activity† | ARC‡ (mean ± SD) |
---|---|---|---|---|
White matter | Uncorrected | 95.26 | 88.31 | 105.00 ± 4.57 |
Sinogram | 99.39 | 98.81 | 103.55 ± 0.60 | |
Image | 99.75 | 96.60 | 102.43 ± 0.24 | |
Right caudate | Uncorrected | 87.03 | 74.56 | 67.11 ± 1.79 |
Sinogram | 93.28 | 90.18 | 104.37 ± 1.34 | |
Image | 95.30 | 98.74 | 95.35 ± 0.84 | |
Left caudate | Uncorrected | 86.55 | 72.02 | 64.53 ± 1.79 |
Sinogram | 92.70 | 94.35 | 99.92 ± 1.41 | |
Image | 96.18 | 97.03 | 94.34 ± 0.67 | |
Right putamen | Uncorrected | 86.57 | 73.78 | 66.13 ± 1.83 |
Sinogram | 91.85 | 96.37 | 97.33 ± 1.54 | |
Image | 94.89 | 96.29 | 92.69 ± 0.89 | |
Left putamen | Uncorrected | 85.22 | 75.29 | 66.62 ± 2.07 |
Sinogram | 88.97 | 95.53 | 95.71 ± 2.12 | |
Image | 93.02 | 98.30 | 93.22 ± 1.25 |