TABLE 2

Cellular S Values for 207Bi

RC (μm)RN (μm)S(C ← C) (Gy/Bq/s)S(C ← CS) (Gy/Bq/s)S(N ← N) (Gy/Bq/s)S(N ← Cy) (Gy/Bq/s)S(N ← CS) (Gy/Bq/s)
322.55E−031.82E−035.35E−032.03E−031.41E−03
312.55E−031.82E−032.03E−022.58E−031.32E−03
431.57E−031.10E−032.55E−031.26E−039.83E−04
421.57E−031.10E−035.35E−031.41E−039.34E−04
541.02E−036.69E−041.57E−037.87E−046.01E−04
531.02E−036.69E−042.55E−039.62E−046.29E−04
521.02E−036.69E−045.35E−031.11E−037.23E−04
656.87E−044.29E−041.02E−034.87E−043.73E−04
646.87E−044.29E−041.57E−035.97E−043.69E−04
636.87E−044.29E−042.55E−037.36E−043.85E−04
764.80E−042.89E−046.87E−043.16E−042.44E−04
754.80E−042.89E−041.02E−033.72E−042.27E−04
744.80E−042.89E−041.57E−034.56E−042.15E−04
734.80E−042.89E−042.55E−035.56E−041.99E−04
873.47E−042.03E−044.80E−042.15E−041.67E−04
863.47E−042.03E−046.87E−042.44E−041.48E−04
853.47E−042.03E−041.02E−032.86E−041.31E−04
843.47E−042.03E−041.57E−033.42E−041.08E−04
982.58E−041.49E−043.47E−041.53E−041.19E−04
972.58E−041.49E−044.80E−041.68E−041.02E−04
962.58E−041.49E−046.87E−041.89E−048.59E−05
952.58E−041.49E−041.02E−032.17E−046.55E−05
1091.97E−041.12E−042.58E−041.12E−048.77E−05
1081.97E−041.12E−043.47E−041.20E−047.32E−05
1071.97E−041.12E−044.80E−041.31E−045.93E−05
1061.97E−041.12E−046.87E−041.45E−044.30E−05
1051.97E−041.12E−041.02E−031.63E−042.30E−05
  • RC = cellular radius; RN = nuclear radius; C = cell volume; CS = cell surface; N = nucleus; Cy = cytoplasm; S(X ← Y) = S factor for X target and Y source.