Biodistribution of 99mTc-HYNIC-IL-8 and 99mTc-HMPAO-Granulocytes in 2 Groups of Rabbits with Experimental Colitis
Parameter | 4 h after injection | P* | |
---|---|---|---|
99mTc-HYNIC-IL-8 (%ID/g) | 99mTc-HMPAO-granulocytes (%ID/g) | ||
Blood | 0.044 ± 0.001 | 0.30 ± 0.03 | <0.007 |
Small intestine | 0.032 ± 0.003 | 0.024 ± 0.003 | <0.06 |
Nonaffected colon tissue | 0.025 ± 0.004 | 0.023 ± 0.008 | <0.70 |
Affected colon tissue | 0.41 ± 0.04 | 0.091 ± 0.055 | <0.007 |
Feces | |||
Nonaffected colon | 0.005 ± 0.001 | 0.015 ± 0.003 | <0.35 |
Affected colon | 0.013 ± 0.002 | 0.022 ± 0.007 | <0.26 |
Lung | 0.27 ± 0.09 | 0.18 ± 0.01 | <0.70 |
Spleen | 0.67 ± 0.22 | 0.83 ± 0.12 | <0.15 |
Kidney | 1.86 ± 0.28 | 0.20 ± 0.01 | <0.007 |
Liver | 0.091 ± 0.005 | 0.21 ± 0.03 | <0.007 |
↵* Mann–Whitney test: 99mTc-HYNIC-IL-8 vs. 99mTc-HMPAO-granulocytes. Level of significance was set at P < 0.05.
Biodistribution of 2 groups of rabbits (5 rabbits per group) is shown at 4 h after injection. Data are expressed as mean ± SEM.