TABLE 1

Patient Data

Patient no.Total body dose (cGy)Administered activity (GBq)Teff (tracer) (h)Initial patient dose rate (mSv/h)Dosimeter* readings (mSv)
Direct readingDaysTLD or OSLDays
1653.8554.80.140.373.80.7012.3
2451.6772.1NA0.6190.509
3651.4885.2NA1.7017
4301.5463.60.091.4671.208
5301.1471.00.060.3860.396
6301.2664.00.040.796.21.0511
7753.0675.60.141.314.21.716
8754.2556.30.141.6872.357
9452.1562.90.050.515.10.715.1
10452.7052.90.080.103.10.173.1
11450.9480.30.030.6830.793
12601.7471.30.091.279
13602.2762.50.090.565.8
14603.2667.60.142.285.93.455.9
15602.2469.40.083.54174.0917
16603.5759.40.181.2151.315
17602.4862.00.110.515
18753.9267.00.121.216.3
19753.8645.50.100.802.1
20751.7677.40.082.1713
21753.5873.00.131.817
22754.7767.90.161.156
High754.77850.183.54174.0917
Low300.94460.030.102.10.173
Average582.61660.101.166.51.448.2
  • * MyDose electronic pocket dosimeter (Aloka Co., Ltd., Tokyo, Japan) used for direct readings. Film badge, TLD, or OSL dosimeter used for verification.

  • Radiation badge shared by >1 individual (e.g., family member) to conservatively determine radiation dose to maximally exposed individual.

  • NA = patients who were released on basis of administered activity (no dose rates were recorded); — = dosimeter was not provided.