TABLE 1

Computational Performance Summary

ModelSensitivity equationsFramesWithout sensitivity equationsWith sensitivity equations
ODEsTime (s)ODEsTime (s)
Blood flowK1, k218 × 5 s30.42690.627
(0.010)(0.005)
FDGK1, k2, k3, k412 × 0.16, 10 × 0.5, 10 × 2, 10 × 5, 4 × 10 min40.504201.144
(0.012)(0.010)
ReceptorK1, k2, kon, koff, Bmax240 × 0.25 min63.9046613.629
(0.071)(0.258)
  • Times are mean (SD) of 10 runs. ODEs is number of ODEs solved and includes output, state, and, if indicated, sensitivity equations. These equations were automatically generated by COMKAT. For blood flow, plasma input function was specified as Cp(t) = 0.055(t/60)6e−t/60/1.8 + 10(t/60)e−t/60/22 + 0.7(t/60)e−t/60/180, t ≥ 0, and blood radioactivity input function as Ca(t) = Cp(t)e−2.033t, with t in minutes. For FDG, plasma input function was specified as Cp(t) = 650 e−6.7t + 146e−0.25t + 105e−0.03t + 21e−0.0001t, t ≥ 0, with t in minutes (26). For receptor, plasma input function was obtained by linearly interpolating input function data for protocol 4 from (8). For both FDG and receptor models, contribution from vascular radioactivity was not included, because these input functions were not available.