TABLE 2.

Coregistration Accuracy for Intrasubject and Template Matching for Perfusion and Receptor Ligand Studies

Study typeIntrasubject registration*Template registration*
Δtot (pixels)Φtot (degrees)Σtot (%)Δtot (pixels)Φtot (degrees)Σtot (%)
[99mTc]ECD
 Obs. 11.1  (0.6)3.0  (2.1)4.4  (2.3)1.4  (0.6)3.1  (1.6)7.8  (3.3)
 Obs. 21.0  (0.4)3.1  (1.8)3.2  (1.8)1.3  (0.5)3.9  (1.7)4.2  (2.0)
 M.I.0.8  (0.4)1.0  (0.6)0.8  (0.3)0.9  (0.4)4.2  (3.5)3.1  (1.7)
 C.D.0.9  (0.4)1.0  (0.6)1.1  (1.1)0.9  (0.4)2.0  (0.7)2.2  (1.6)
 U.I.0.9  (0.4)1.1  (0.6)1.1  (0.3)3.1  (1.5)§§
[123I]IBZM
 Obs. 11.1  (0.3)2.8  (1.3)2.9  (1.5)1.4  (0.3)3.8  (1.7)6.6  (2.1)
 Obs. 21.1  (0.4)2.2  (0.7)3.1  (2.0)0.9  (0.2)2.6  (1.0)3.7  (2.5)
 M.I.0.9  (0.3)1.0  (0.6)1.6  (0.4)0.9  (0.3)1.6  (1.0)1.9  (1.7)
 C.D.0.9  (0.3)0.9  (0.6)1.2  (1.3)1.0  (0.4)1.2  (1.0)1.3  (1.2)
 U.I.0.8  (0.3)1.0  (0.6)3.4  (5.2)1.0  (0.4)1.3  (0.7)6.7  (4.6)
[123I]β-CIT
 Obs. 12.1  (1.8)7.2  (4.2)7.5  (2.5)1.9  (1.5)8.4  (3.0)7.1  (3.7)
 Obs. 21.8  (1.6)8.1  (5.9)9.5  (6.6)2.0  (1.6)7.7  (5.0)6.5  (4.4)
 M.I.1.3  (1.4)3.4  (4.7)§2.3  (2.2)8.6  (8.3)§
 C.D.1.7  (1.5)6.9  (9.4)6.7  (7.5)3.1  (3.3)§§
 U.I.4.8  (4.4)5.7  (4.8)8.7  (3.9)§§§
[123I]R91150
 Obs. 11.7  (2.5)2.5  (1.4)2.9  (1.9)1.9  (1.4)6.9  (3.6)7.9  (4.3)
 Obs. 21.2  (0.4)3.2  (1.9)3.2  (2.0)1.7  (0.8)6.0  (2.2)8.3  (3.6)
 M.I.0.9  (0.3)1.1  (0.6)0.8  (0.3)0.9  (0.6)2.9  (1.6)3.0  (2.5)
 C.D.0.9  (0.5)1.1  (0.6)0.9  (0.7)1.3  (0.9)3.7  (2.4)4.3  (3.9)
 U.I.0.9  (0.3)1.0  (0.6)1.6  (0.5)§§§
TCT
 Obs. 11.3  (1.2)1.8  (1.0)2.4  (1.5)1.3  (0.5)3.5  (2.3)3.7  (1.8)
 Obs. 21.1  (0.6)1.7  (1.1)2.5  (2.3)1.6  (0.7)2.5  (1.4)3.6  (1.9)
 M.I.0.9  (0.4)1.3  (0.6)1.6  (2.4)0.8  (0.3)4.2  (3.3)2.8  (3.0)
 C.D.0.9  (0.4)1.2  (0.7)1.0  (0.8)0.9  (0.4)2.4  (1.5)1.2  (0.7)
 U.I.§§§§§§
  • * Values are given as mean and SD.

  • P < 0.01.

  • P < 0.05.

  • § Out of limits (>6 pixels or >10° or >10% mismatch).