Particle Size Diameter of Reported Colloids
Colloidal agent | Particle size (nm) | Percentage | Reference |
---|---|---|---|
Microaggregated albumin (nanocolloid) | <80 | 95 | 12 |
Rhenium sulfide | 4–12 | — | 16 |
Sulfur colloid | 100–300 | — | 16 |
305–340 | — | 15 | |
Lyocoll* | <200 | 74.4 | |
200–1,000 | 22.4 | 29 | |
TCK-1† | <200 | 58.2 | |
200–1,000 | 24.0 | ||
1,000–3,000 | 7.8 | ||
>3,000 | 10.0 | 29 | |
0.1-μm filtered | 10 | — | |
89–173 | <0.1 | 15 | |
>200 | 56.8‡ | ||
30–200 | 7.3‡ | ||
<30 | 36.2‡ | 12 | |
Antimony trisulfide | 38.1 ± 3.0 | — | 37 |
3–15 or 10–25 | — | 18 | |
3–18 | — | 24 | |
∼9 | — | 38 | |
<30 | — | 25 | |
4–10 | — | 39 |
↵* Mallinckrodt Diagnostica, Petten, Holland.
↵† Oris-Industrie, Cedex, France.
↵‡ 48.3% were >0.2 μm, 5.4% were 0.2–0.03 μm, and 46.7% were <0.03 μm with old 99mTc-pertechnetate milked; 83.2% were >0.2 μm, 2.2% were 0.2–0.3 μm, and 14.7% were <0.03 μm with prolonged heating and freshly milked 99mTc-pertechnetate.