TABLE 1.

FDA-Approved Diagnostic Agents

AgentAmountImage displayNumber of regions for a positive scan
Amyloid
Florbetapir F-18370 MBq (10 mCi)Color scale: gray scale or inverse gray scale2, or only 1 if gray matter uptake exceeds white matter uptake
Regions: temporal, parietal (including precuneus), frontal, and occipital
Flutemetamol F-18185 MBq (5 mCi)Color scale: rainbow or Sokoloff; color scale is adjusted to set pons to approximately 90% maximum intensity1
Regions: temporal, parietal, posterior cingulate/precuneus, frontal, striatum
Florbetaben F-18300 MBq (8.1 mCi)Color scale: gray scale or inverse gray scale1
Regions: temporal, parietal, posterior cingulate/precuneus, and frontal
Tau
Flortaucipir F-18370 MBq (10 mCi)Color scale: color scale with rapid transition between 2 distinct colors, scale being adjusted so that transition occurs at 1.65-fold threshold; neocortical activity in either hemisphere contributes to image interpretationPositive scan shows increased neocortical activity in posterolateral temporal, occipital, or parietal/precuneus region(s), with or without frontal activity; neocortical activity in either hemisphere can contribute to identification of positive pattern (31,32)