TABLE 1.

Brain [18F]FDG PET/MRI Parameters

ModalityParameterSpecification
[18F]FDG PETImage protocol30-min static acquisition
Image planeAxial
Slice thickness (mm)2.78
Field of view (cm)60
Matrix size (mm)192 × 192
Reconstruction algorithmTime of flight (28 subsets, 8 iterations)
Glucose uptake (mg/dL)85.9 ± 10.16 (mean ± SD)
Dose (MBq/kg)176.49 ± 42.55 (mean ± SD)
Uptake time (min)43.50 ± 6.67 (mean ± SD)
MRI*3D inversion recovery fast SPGR
 Image planeAxial
 Slice thickness (mm)1
 Field of view (cm)27
 Matrix size (mm)256 × 256
 Echo time (ms)3.1
 Repetition time (ms)7,664
 Flip angle11°
 Number of excitations1.00
2D diffusion-weighted imaging
 Image planeAxial
 Slice thickness (mm)5
 Field of view (cm)24
 Matrix size (mm)128 × 128
 Echo time (ms)76.5
 Repetition time (ms)5,000
 Flip angle90°
 Number of excitations3.00
3D arterial spin labeling
 Image planeAxial
 Slice thickness (mm)4
 Field of view (cm)24
 Matrix size (mm)512 × 8
 Echo time (ms)10.7
 Repetition time (ms)4,854
 Flip angle111°
 Number of excitations3.00
  • * 3D T2 fluid-attenuated inversion recovery and 3D multiple-echo gradient-echo (QSM/R2*) sequences were also acquired.

  • Diffusion-weighted images were acquired with 2 diffusion weightings (b = 0 and 1,000 s/mm2). Apparent diffusion coefficient maps were automatically generated by software. Postprocessed arterial spin labeling imaging was performed by automated reconstruction script that sent CBF images directly to PACS.