TABLE 2.

Comparison of Normal-Organ SUVmax Between 68Ga-NODAGA-JR11 and 68Ga-DOTATATE PET/CT

OrganJR11TATEP
Spleen (n = 43)*8.4 ± 4.217.7 ± 5.50.000
Renal cortex (n = 48)10.2 ± 3.211.9 ± 2.80.006
Adrenal glands (n = 48)7.1 ± 3.711.8 ± 4.50.000
Pituitary gland (n = 48)5.7 ± 2.87.8 ± 3.00.000
Stomach wall (n = 48)1.4 ± 0.61.9 ± 1.00.002
Lung (n = 48)0.5 ± 0.20.3 ± 0.10.000
Normal liver parenchyma (n = 48)3.9 ± 1.97.1 ± 2.00.000
Small intestine (n = 48)1.7 ± 0.72.5 ± 1.30.001
Pancreas (uncinate process, n = 41)3.3 ± 2.24.7 ± 2.50.008
Bone marrow (L5 vertebra, n = 45)1.2 ± 0.41.5 ± 0.40.000
  • * Splenectomy was done in 5 patients.

  • Pancreas uptake measurement was ruled out in 7 patients because of focal lesions in uncinate process or partial or total pancreatectomy.

  • Bone marrow uptake for focal lesions in L5 vertebra could not be measured in 3 patients.

  • Data are expressed as mean ± SD.