TABLE 1.

Tumor Uptake of Various PSMA-Targeting Tracers

No.RadioligandTime after injection (min)SUVmaxSUVmeanTBRmax/max
1[68Ga]Ga-PSMA-1190 (WB)15.34.432.6
16520.04.566.7
24017.04.038.6
2[68Ga]Ga-PSMA-1190 (WB)3.61.7359.0
1655.92.9295.0
2405.82.835.9
3[68Ga]Ga-PSMA-1190 (WB)7.42.5185.3
1659.82.698.4
24010.02.826.3
4[68Ga]Ga-PSMA-1190 (WB)6.53.110.3
1659.03.517.3
2409.03.67.5
5[68Ga]Ga-PSMA-1190 (WB)7.31.966.6
1657.72.329.5
2409.02.664.6
6[18F]DCFPyl804.52.121.9
NA (WB)NANANA
1406.82.925.7
7[18F]DCFPyl805.32.123.5
95 (WB)4.52.313.6
1407.42.724.4
8[18F]DCFPyl8010.34.634.8
95 (WB)12.65.329.9
14013.16.036.5
9[68Ga]Ga-PSMA-11602.21.072.3
10[68Ga]Ga-PSMA-11601.30.610.3
11[18F]PSMA-10071203.41.66.1
12[18F]PSMA-10071208.13.410.1
13[18F]PSMA-100712014.66.839.6
14[18F]PSMA-100712012.44.77.8
  • TBRmax/max = SUVmax tumor divided by SUVmax background; WB = whole body; NA = not available.