TABLE 1.

Characteristic Properties of Elementally Matched Theranostic Isotope Pairs

DiagnosticTherapeutic
RadionuclideHalf-lifeDecayEnergy* (keV)RadionuclideHalf-lifeDecayEnergy* (keV)Reference
203Pb51.8 hEC (100%)279 (81%)212Pb10.6 hβ (100%)β: 40.9 (5%), 93.3 (81.5%), 171.4 (13.7%), γ: 238 (46.3%)(8,22)
64Cu12.7 hβ+ (17.8%), EC (43.8%)511 (35%), 1,345 (0.5%)67Cu61.9 hβ (100%)395 (45%), 484 (35%), 577 (20%)(23,24)
86Y14.7 hβ+ (31.9%), EC (68.1%)443 (16.9%) 628 (32.6%)90Y64 hβ (100%)932.4 (99.9%)(25,26)
124I4.2 dβ+603 (61%), 1,691 (11%)131I8 dβ (100%)284 (6.14%), 365 (81.7%), 637 (7.17%)(27,28)
152Tb17.5 hβ+ + EC (100%)344 (63.5%)149Tb4.1 hα (17.7%)α: 3 967(29,30)
149Tb4.1 hEC (82.3%)165 (26.7%), 352 (29.8%), 388.6 (18.6%)161Tb6.9 dβ (100%)137.7 (25.7%), 157.4 (65%)
155Tb5.3 dEC (100%)86.5 (32%), 105.3 (25%), 180 (7.5%)
43Sc3.9 hβ+ (98%),373 (22.5%)47Sc3.3 dβ (100%)159.4 (68%)(3135)
44gSc3.9 hβ+ (94%)1,157 (100%)
  • * Intensity.

  • EC = electron capture.