TABLE 1.

Physical Characteristics of the Commonly Used Theranostics Pairs 68Ga/177Lu and 68Ga/90Y

Physical characteristics*
Energy [keV]
RadionuclidesGammaBeta or AlphaHalf-lifePharmaceuticalsUse
68Ga511 (caused by annihilation)1899 (β+)1.13 h[68Ga]Ga-PSMA-11 [68Ga]Ga-PSMA-I&T [68Ga]Ga-DOTA-TATE (NETSPOTTM) [68Ga]Ga-DOTA-TOC (SomaKIT TOC®)Diagnostic
18F511 (caused by annihilation)634 (β+)1.83 hPiflufolastat F18 (Pylarify®) [18F]F PSMA-1007 [18F]DCFPyL
177Lu113 (6%) 208 (11%)498 (β)6.73 d[177Lu]Lu-PSMA-617 [177Lu]Lu-PSMA-I&T [177Lu]Lu-DOTA-TATE (Lutathera®)Therapy
90YBremsstrahlung2280 (β)2.67 d[90Y]Y-DOTA-TOC
99mTc140 (89%)not relevant6.01 h[99mTc]Tc-MDP [99mTc]Tc-DPD [99mTc]Tc-HDPDiagnostic
223Ra154 (6%) 269 (14%)5716 (α), 5606 (α), 6819 (α), 7386 (α), 6623 (α) 1370 (β) 1420 (β)11.44 d223RaCl2 (Xofigo®)Therapy