Radiolabeling Yields for 125I/211At-3-Lu
Radionuclide | Starting radioactivity | Age of 211At | Method of preparation | n | % yield* |
---|---|---|---|---|---|
125I | 0.170–0.266 GBq (4.6–7.2 mCi) | Not applicable | A | 2 | 46.5 ± 7.7 |
125I | 0.054–0.518 GBq (1.47–14 mCi) | Not applicable | B | 4 | 62.8 ± 9.0 |
211At | 0.16–0.31 GBq (4.4–8.5 mCi) | Fresh | A | 3 | 6.3 ± 1.8 |
211At | 0.126- 0.34 GBq (3.4–9.2 mCi) | Fresh | B | 2 | 17.8 ± 8.2 |
211At | 0.44–0.66 GBq (12.0–17.0 mCi) | ≥9 h | A | 2 | 8.6 ± 3.6 |
211At | 0.115–0.877 GBq (3.1–23.7 mCi) | ≥9 h | B | 4 | 13.6 ± 8.4 |
↵* After preparative high-performance liquid chromatography purification.
A = separate preparative high-performance liquid chromatography purification of 125I/211At-3 and 125I/211At-3-Lu. B = preparative high-performance liquid chromatography purification of 125I/211At-3-Lu only.