TY - JOUR T1 - Tumor-to-Blood Ratio for Assessment of Somatostatin Receptor Density in Neuroendocrine Tumors Using <sup>68</sup>Ga-DOTATOC and <sup>68</sup>Ga-DOTATATE JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 217 LP - 221 DO - 10.2967/jnumed.119.228072 VL - 61 IS - 2 AU - Ezgi Ilan AU - Irina Velikyan AU - Mattias Sandström AU - Anders Sundin AU - Mark Lubberink Y1 - 2020/02/01 UR - http://jnm.snmjournals.org/content/61/2/217.abstract N2 - PET/CT with 68Ga-DOTA-somatostatin analogs has been tested for therapy monitoring in patients with neuroendocrine tumors (NETs). However, SUVs in tumors do not correlate with the net influx rate (Ki), as a representation of the somatostatin receptor expression. In this study, tumor-to-blood ratio (TBR) was evaluated as an alternative tool for semiquantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake and as a therapy monitoring tool for patients with NETs. Methods: Twenty-two NET patients underwent a 45-min dynamic PET/CT scan after injection of 68Ga-DOTATOC or 68Ga-DOTATATE. Ki was determined using the Patlak method, and TBR was calculated for the 40- to 45-min interval. Results: A linear relation was found between Ki and TBR, with a square of Pearson correlation of 0.98 and 0.93 for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. Conclusion: A high correlation was found between Ki and TBR. Hence, TBR reflects somatostatin receptor density more accurately than SUV and is suggested as the preferred metric for semiquantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake. ER -