TY - JOUR T1 - Prospective Evaluation of a Tumor Control Probability Model Based on Dynamic <sup>18</sup>F-FMISO PET for Head and Neck Cancer Radiotherapy JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 1698 LP - 1704 DO - 10.2967/jnumed.119.227744 VL - 60 IS - 12 AU - Daniela Thorwarth AU - Stefan Welz AU - David Mönnich AU - Christina Pfannenberg AU - Konstantin Nikolaou AU - Matthias Reimold AU - Christian La Fougère AU - Gerald Reischl AU - Paul-Stefan Mauz AU - Frank Paulsen AU - Markus Alber AU - Claus Belka AU - Daniel Zips Y1 - 2019/12/01 UR - http://jnm.snmjournals.org/content/60/12/1698.abstract N2 - Our purpose was to evaluate an imaging parameter–response relationship between the extent of tumor hypoxia quantified by dynamic 18F-fluoromisonidazole (18F-FMISO) PET/CT and the risk of relapse after radiotherapy in patients with head and neck cancer. Methods: Before a prospective cohort of 25 head and neck cancer patients started radiotherapy, they were examined with dynamic 18F-FMISO PET/CT 0–240 min after tracer injection. 18F-FMISO image parameters, including a hypoxia metric, MFMISO, derived from pharmacokinetic modeling of dynamic 18F-FMISO and maximum tumor-to-muscle ratio (TMRmax) at 4 h after injection, gross tumor volume (GTV), relative hypoxic volume based on MFMISO, and a logistic regression model combining GTV and TMRmax, were assessed and compared with a previous training cohort (n = 15). Dynamic 18F-FMISO was used to validate a tumor control probability model based on MFMISO. The prognostic potential with respect to local control of all potential parameters was validated using the concordance index for univariate Cox regression models determined from the training cohort, in addition to Kaplan–Meier analysis including the log-rank test. Results: The tumor control probability model was confirmed, indicating that dynamic 18F-FMISO allows stratification of patients into different risk groups according to radiotherapy outcome. In this study, MFMISO was the only parameter that was confirmed as prognostic in the independent validation cohort (concordance index, 0.71; P = 0.004). All other investigated parameters, such as TMRmax, GTV, relative hypoxic volume, and the combination of GTV and TMRmax, were not able to stratify patient groups according to outcome in this validation cohort (P = not statistically significant). Conclusion: In this study, the relationship between MFMISO and the risk of relapse was prospectively validated. The data support further evaluation and external validation of dynamic 18F-FMISO PET/CT as a promising method for patient stratification and hypoxia-based radiotherapy personalization, including dose painting. ER -