RT Journal Article SR Electronic T1 Dixon-VIBE Deep Learning (DIVIDE) Pseudo-CT Synthesis for Pelvis PET/MR Attenuation Correction JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 429 OP 435 DO 10.2967/jnumed.118.209288 VO 60 IS 3 A1 Angel Torrado-Carvajal A1 Javier Vera-Olmos A1 David Izquierdo-Garcia A1 Onofrio A. Catalano A1 Manuel A. Morales A1 Justin Margolin A1 Andrea Soricelli A1 Marco Salvatore A1 Norberto Malpica A1 Ciprian Catana YR 2019 UL http://jnm.snmjournals.org/content/60/3/429.abstract AB Whole-body attenuation correction (AC) is still challenging in combined PET/MR scanners. We describe Dixon-VIBE Deep Learning (DIVIDE), a deep-learning network that allows synthesizing pelvis pseudo-CT maps based only on the standard Dixon volumetric interpolated breath-hold examination (Dixon-VIBE) images currently acquired for AC in some commercial scanners. Methods: We propose a network that maps between the four 2-dimensional (2D) Dixon MR images (water, fat, in-phase, and out-of-phase) and their corresponding 2D CT image. In contrast to previous methods, we used transposed convolutions to learn the up-sampling parameters, we used whole 2D slices to provide context information, and we pretrained the network with brain images. Twenty-eight datasets obtained from 19 patients who underwent PET/CT and PET/MR examinations were used to evaluate the proposed method. We assessed the accuracy of the μ-maps and reconstructed PET images by performing voxel- and region-based analysis comparing the SUVs (in g/mL) obtained after AC using the Dixon-VIBE (PETDixon), DIVIDE (PETDIVIDE), and CT-based (PETCT) methods. Additionally, the bias in quantification was estimated in synthetic lesions defined in the prostate, rectum, pelvis, and spine. Results: Absolute mean relative change values relative to CT AC were lower than 2% on average for the DIVIDE method in every region of interest except for bone tissue, where it was lower than 4% and 6.75 times smaller than the relative change of the Dixon method. There was an excellent voxel-by-voxel correlation between PETCT and PETDIVIDE (R2 = 0.9998, P < 0.01). The Bland–Altman plot between PETCT and PETDIVIDE showed that the average of the differences and the variability were lower (mean PETCT–PETDIVIDE SUV, 0.0003; PETCT–PETDIVIDE SD, 0.0094; 95% confidence interval, [−0.0180,0.0188]) than the average of differences between PETCT and PETDixon (mean PETCT–PETDixon SUV, 0.0006; PETCT–PETDixon SD, 0.0264; 95% confidence interval, [−0.0510,0.0524]). Statistically significant changes in PET data quantification were observed between the 2 methods in the synthetic lesions, with the largest improvement in femur and spine lesions. Conclusion: The DIVIDE method can accurately synthesize a pelvis pseudo-CT scan from standard Dixon-VIBE images, allowing for accurate AC in combined PET/MR scanners. Additionally, our implementation allows rapid pseudo-CT synthesis, making it suitable for routine applications and even allowing retrospective processing of Dixon-VIBE data.