RT Journal Article SR Electronic T1 Immunohistochemical Validation of PSMA Expression Measured by 68Ga-PSMA PET/CT in Primary Prostate Cancer JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 238 OP 243 DO 10.2967/jnumed.117.195172 VO 59 IS 2 A1 Nadine Woythal A1 Ruza Arsenic A1 Carsten Kempkensteffen A1 Kurt Miller A1 Jan-Carlo Janssen A1 Kai Huang A1 Marcus R. Makowski A1 Winfried Brenner A1 Vikas Prasad YR 2018 UL http://jnm.snmjournals.org/content/59/2/238.abstract AB 68Ga-labeled prostate-specific membrane antigen (68Ga-PSMA) PET/CT has a proven role in staging and restaging of prostate cancer (PCA). The aims of this study were to evaluate the association of intraprostatic 68Ga-PSMA PET/CT findings and PSMA expression in immunohistochemical staining and generate a cutoff value for differentiation between normal prostate (PN) and PCA. Methods: The data of 31 patients (mean age, 67.2 y) who underwent prostatectomy and preoperative PET were retrospectively analyzed. On PET, focally increased uptake in the prostate was suggestive of tumor. A region of interest was placed on the suggestive area to generate an SUVmax; a similar region of interest was placed on adjacent visually PN. Both PCA and PN were stained with monoclonal anti-PSMA antibody (clone 3E6, 1:100, M3620). Results: All intraprostatic PCA lesions on PET could be confirmed histopathologically. In PN sections (n = 31), median staining intensity was mild, median percentage of stained cells was 20% ± 14.24%, and median immunoreactive score (IRS) was 1. In PCA sections (n = 31), median IRS was 3, median staining intensity was strong, and median percentage of stained cells was 80% ± 16.46%. The mean SUVmax (±SD) of PCA (14.06 ± 15.56) was significantly higher than that of PN (2.43 ± 0.63; P < 0.001). Receiver-operating-characteristic curve analyses of the SUVmax of PCA, validated by immunohistochemical staining in 62 tissue samples, showed the best cutoff to be 3.15 (sensitivity, 97%; specificity, 90%; area under curve, 0.987). Applied to multifocal PCA, it resulted in sensitivity and specificity of 87% and 97% respectively. The mean SUVmax of PCA and PN for an IRS of less than 2 (n = 26; 2.52 ± 0.64) was significantly lower than the mean SUVmax for an IRS of 2 or more (n = 36; 12.38 ± 15.02; P < 0.001). The mean SUVmax was significantly lower in PCA samples with fewer than 50% stained cells (n = 30; 2.81 ± 2.35) than in samples with 50% or more (n = 32; 13.34 ± 15.55; P < 0.001). There was no correlation between the SUVmax of PCA and Gleason score (P = 0.54). Conclusion: This study showed that SUVmax on 68Ga-PSMA PET/CT correlates significantly with PSMA expression in primary PCA, enabling the detection of PCA with a high sensitivity and specificity.