RT Journal Article SR Electronic T1 Parametric Net Influx Rate Images of 68Ga-DOTATOC and 68Ga-DOTATATE: Quantitative Accuracy and Improved Image Contrast JF Journal of Nuclear Medicine JO J Nucl Med FD Society of Nuclear Medicine SP 744 OP 749 DO 10.2967/jnumed.116.180380 VO 58 IS 5 A1 Ezgi Ilan A1 Mattias Sandström A1 Irina Velikyan A1 Anders Sundin A1 Barbro Eriksson A1 Mark Lubberink YR 2017 UL http://jnm.snmjournals.org/content/58/5/744.abstract AB 68Ga-DOTATOC and 68Ga-DOTATATE are radiolabeled somatostatin analogs used for the diagnosis of somatostatin receptor–expressing neuroendocrine tumors (NETs), and SUV measurements are suggested for treatment monitoring. However, changes in net influx rate (Ki) may better reflect treatment effects than those of the SUV, and accordingly there is a need to compute parametric images showing Ki at the voxel level. The aim of this study was to evaluate parametric methods for computation of parametric Ki images by comparison to volume of interest (VOI)–based methods and to assess image contrast in terms of tumor-to-liver ratio. Methods: Ten patients with metastatic NETs underwent a 45-min dynamic PET examination followed by whole-body PET/CT at 1 h after injection of 68Ga-DOTATOC and 68Ga-DOTATATE on consecutive days. Parametric Ki images were computed using a basis function method (BFM) implementation of the 2-tissue-irreversible-compartment model and the Patlak method using a descending aorta image–derived input function, and mean tumor Ki values were determined for 50% isocontour VOIs and compared with Ki values based on nonlinear regression (NLR) of the whole-VOI time–activity curve. A subsample of healthy liver was delineated in the whole-body and Ki images, and tumor-to-liver ratios were calculated to evaluate image contrast. Correlation (R2) and agreement between VOI-based and parametric Ki values were assessed using regression and Bland–Altman analysis. Results: The R2 between NLR-based and parametric image–based (BFM) tumor Ki values was 0.98 (slope, 0.81) and 0.97 (slope, 0.88) for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. For Patlak analysis, the R2 between NLR-based and parametric-based (Patlak) tumor Ki was 0.95 (slope, 0.71) and 0.92 (slope, 0.74) for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. There was no bias between NLR and parametric-based Ki values. Tumor-to-liver contrast was 1.6 and 2.0 times higher in the parametric BFM Ki images and 2.3 and 3.0 times in the Patlak images than in the whole-body images for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. Conclusion: A high R2 and agreement between NLR- and parametric-based Ki values was found, showing that Ki images are quantitatively accurate. In addition, tumor-to-liver contrast was superior in the parametric Ki images compared with whole-body images for both 68Ga-DOTATOC and 68Ga DOTATATE.