TY - JOUR T1 - Head-to-Head Comparison of <sup>64</sup>Cu-DOTATATE and <sup>68</sup>Ga-DOTATOC PET/CT: A Prospective Study of 59 Patients with Neuroendocrine Tumors JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 451 LP - 457 DO - 10.2967/jnumed.116.180430 VL - 58 IS - 3 AU - Camilla B. Johnbeck AU - Ulrich Knigge AU - Annika Loft AU - Anne K. Berthelsen AU - Jann Mortensen AU - Peter Oturai AU - Seppo W. Langer AU - Dennis R. Elema AU - Andreas Kjaer Y1 - 2017/03/01 UR - http://jnm.snmjournals.org/content/58/3/451.abstract N2 - Somatostatin receptor imaging is a valuable tool in the diagnosis, follow-up, and treatment planning of neuroendocrine tumor (NET). PET-based tracers using 68Ga as the radioisotope have in most centers replaced SPECT-based tracers as the gold standard. 64Cu-DOTATATE is a new PET tracer that has been shown to be far superior to the SPECT tracer 111In-diethylenetriaminepentaacetic acid-octreotide. Because of the advantages of 64Cu over 68Ga, we hypothesized that the tracer has a higher sensitivity than 68Ga-based tracers. To test this hypothesis, we compared on a head-to-head basis the diagnostic performance of 64Cu-DOTATATE with that of 68Ga-DOTATOC in NET patients. Methods: Fifty-nine NET patients were scanned with both 64Cu-DOTATATE and 68Ga-DOTATOC PET/CT and compared on a head-to-head basis. Discordant lesions were verified during at least 30 mo of follow-up. Results: A total of 701 lesions were concordantly detected on both 64Cu-DOTATATE and 68Ga-DOTATOC PET/CT scans, whereas an additional 68 lesions were found by only one of the scans. 64Cu-DOTATATE showed 42 lesions not found on 68Ga-DOTATOC, of which 33 were found to be true-positive on follow-up. 68Ga-DOTATOC showed 26 lesions not found on 64Cu-DOTATATE, of which 7 were found to be true-positive on follow-up. False-positives were mainly lymph node lesions. Accordingly, 83% of the additional true lesions found on only one of the scans were found by 64Cu-DOTATATE. On a patient-basis, additional true lesions were found by 64Cu-DOTATATE and 68Ga-DOTATOC in 13 and 3 patients, respectively. All patients with additional lesions also had concordant lesions found by both scans. Conclusion: 64Cu-DOTATATE has advantages over 68Ga-DOTATOC in the detection of lesions in NET patients. Although patient-based sensitivity was the same for 64Cu-DOTATATE and 68Ga-DOTATOC in this cohort, significantly more lesions were detected by 64Cu-DOTATATE. Furthermore, the shelf life of more than 24 h and the scanning window of at least 3 h make 64Cu-DOTATATE favorable and easy to use in the clinical setting. ER -