PT - JOURNAL ARTICLE AU - Bouvet, Vincent AU - Wuest, Melinda AU - Wiebe, Leonard AU - Wuest, Frank TI - Synthesis of [18F]FAZA using micro-fluidic technology DP - 2010 May 01 TA - Journal of Nuclear Medicine PG - 1449--1449 VI - 51 IP - supplement 2 4099 - http://jnm.snmjournals.org/content/51/supplement_2/1449.short 4100 - http://jnm.snmjournals.org/content/51/supplement_2/1449.full SO - J Nucl Med2010 May 01; 51 AB - 1449 Objectives [18F]FAZA is a frequently used radiotracer for PET imaging of hypoxia. Current automated synthesis of [18F]FAZA involves a 5 min [18F]fluoride incorporation on 1-(2,3-di-O-acetyl-5-O-tosyl-a-D-arabinofuranosyl)-2-nitroimidazole followed by a 2 min hydrolysis step. However, the overall radiochemical yield (RCY) is reported to be low. Microfluidic technology is a rapidly evolving novel technique enabling micro-scale chemical reactions. This technology allows fast reactions in a simple experimental set-up, while using only very low amounts of starting material. The present study describes radiosynthesis of [18F]FAZA by means of micro-fluidic technology. Methods Radiosynthesis in a microfluidic apparatus was optimized through varying various reaction parameters like temperature (80°C to 140°C), flow rate (8 uL x min-1 to 40 uL x min-1), reaction time (using different length of reactor), solvent (DMSO or CH3CN), and precursor concentration (2.5 mg x mL-1 to 5 mg x mL-1). Results Optimal reaction conditions for [18F]fluoride incorporation were developed for small scale (0.1 MBq to 100 MBq) and large scale preparations (400 Mq to 2 GBq). Best reaction conditions at small scale include a reaction temperature of 120°C, a flow rate of 18 uL x min-1 for 5 min 20 sec, DMSO as solvent, and a precursor concentration of 2.5 mg x mL-1. These conditions afforded purified [18F]FAZA in 72% RCY. Large scale synthesis of [18F]FAZA employed a reaction temperature of 120°C, a flow rate of 28 uL x min-1 for 4 min 10 sec, DMSO as the solvent, and a precursor concentration of 5 mg x mL-1. These conditions gave HPLC-purified [18F]FAZA in 29 % RCY. Subsequent radiopharmacological evaluation of [18F]FAZA involved dynamic small animal PET studies in EMT-6 tumor bearing mice. Conclusions Application of microfluidic technology significantly improved radiochemical yields of [18F]FAZA. Microfluidic technology represents an interesting alternative for the synthesis of clinically relevant PET radiotracers like [18F]FAZA. Future work is focused on the use of larger starting activities of [18F]fluoride (>5 GBq)