PT - JOURNAL ARTICLE AU - Byun, Byung Hyun AU - Lim, Sang Moo AU - Pai, Moon Sun AU - Cheon, Gi Jeong AU - Choi, Chang Woon AU - Lee, Byeong-Cheol AU - Lee, Guk-Haeng AU - Lee, Yong-Sik AU - Shim, Youn-Sang TI - Diagnostic performance of preoperative FDG-PET for the detection of metastatic cervical lymph nodes in recurrent papillary thyroid carcinoma patients with negative I-131 whole body scans DP - 2007 May 01 TA - Journal of Nuclear Medicine PG - 264P--264P VI - 48 IP - supplement 2 4099 - http://jnm.snmjournals.org/content/48/supplement_2/264P.1.short 4100 - http://jnm.snmjournals.org/content/48/supplement_2/264P.1.full SO - J Nucl Med2007 May 01; 48 AB - 1200 Objectives: We evaluated the diagnostic performance of FDG-PET for the detection of metastatic cervical lymph nodes in recurrent papillary thyroid carcinoma patients with negative I-131 scan. Methods: Nineteen patients with papillary thyroid carcinoma who had total thyroidectomy and I-131 ablation therapy were included. In the follow-up period, FDG-PET showed suspected cervical lymph nodes metastases and neck dissection was performed within 3 months after FDG-PET. They were negative on I-131 WBS, but showed suspicious metastatic findings on FDG-PET, CT scan, and US. Except for patients with elevated Tg antiboby levels, all patients showed the serum Tg levels ≥10ng/ml (83.2 ± 119.1) at the TSH of ≥30uIU/ml. Pathologic results of lymph nodes were compared with FDG-PET findings. The size of lymph node was measured by preoperative CT scan or US. Results: In 45 cervical lymph node groups dissected, 31 lymph node groups were metastasis. The sensitivity and specificity of FDG-PET for metastasis were 74.2% (23 of 31) and 50.0% (7 of 14), respectively. Eight lesions with metastasis showed no abnormal FDG uptake (false negative), and none of them exceeded 8mm in size (4 to 8mm, median= 6mm). On the other hand, twenty-three metastatic lesions with abnormal FDG uptake (true positive) were variable in size (6 to 17mm, median=9mm). Conclusions: FDG-PET is suitable for the detection of metastatic cervical lymph nodes in patients with negative I-131 scan. However, small sized lymph nodes could not be detected on FDG-PET.