PT - JOURNAL ARTICLE AU - Florent Cachin AU - Elisabeth Miot-Noirault AU - Brigitte Gillet AU - Vanina Isnardi AU - Bruno Labeille AU - Pierre Payoux AU - Nicolas Meyer AU - Serge Cammilleri AU - Caroline Gaudy AU - Micheline Razzouk-Cadet AU - Jean Philippe Lacour AU - Florence Granel-Brocard AU - Christelle Tychyj AU - Fathalah Benbouzid AU - Jean Daniel Grange AU - Françoise Baulieu AU - Antony Kelly AU - Charles Merlin AU - Danielle Mestas AU - Françoise Gachon AU - Jean Michel Chezal AU - Françoise Degoul AU - Michel D’Incan TI - <sup>123</sup>I-BZA2 as a Melanin-Targeted Radiotracer for the Identification of Melanoma Metastases: Results and Perspectives of a Multicenter Phase III Clinical Trial AID - 10.2967/jnumed.113.123554 DP - 2014 Jan 01 TA - Journal of Nuclear Medicine PG - 15--22 VI - 55 IP - 1 4099 - http://jnm.snmjournals.org/content/55/1/15.short 4100 - http://jnm.snmjournals.org/content/55/1/15.full SO - J Nucl Med2014 Jan 01; 55 AB - Our group has developed a new radiopharmaceutical, 123I-N-(2-diethylaminoethyl)-2-iodobenzamide (123I-BZA2), a benzamide derivative able to bind to melanin pigment in melanoma cells. In a prospective and multicentric phase III clinical study, the value of 18F-FDG PET/CT and 123I-BZA2 scintigraphy was compared for melanoma staging. Methods: Patients with a past history of cutaneous or ocular melanoma were included from 8 hospitals. 18F-FDG imaging was performed according to a standard PET protocol. Whole-body, static planar, and SPECT/CT (if available) images were acquired 4 h after injection of a 2 MBq/kg dose of 123I-BZA2. 18F-FDG and 123I-BZA2 sensitivity and specificity for the diagnosis of melanoma metastasis were calculated and compared on both a lesion basis and a patient basis. True-positive and true-negative lesion status was determined after 6 mo of clinical follow-up or according to lesion biopsies (if available). Melanin content in biopsies was evaluated with the standard Fontana–Masson silver method and was correlated with 123I-BZA2 uptake. Based on statistical analysis, the number of inclusions was estimated at 186. Results: In all, 87 patients were enrolled from 2008 to 2010. Of these, 45 (52%) had metastases. A total of 338 imaging abnormalities were analyzed; 86 lesions were considered metastases, and 20 of 25 lesion biopsies found melanoma metastases. In a patient-based analysis, the sensitivity of 18F-FDG for diagnosis of melanoma metastases was higher than that of 123I-BZA2, at 87% and 39%, respectively (P &lt; 0.05). For specificity, 18F-FDG and 123I-BZA2 were not statistically different, at 78% and 94%, respectively. In a lesion-based analysis, the sensitivity of 18F-FDG was statistically higher than that of 123I-BZA2 (80% vs. 23%, P &lt; 0.05). The specificity of 18F-FDG was lower than that of 123I-BZA2 (54% vs. 86%, P &lt; 0.05). According to biopsy analysis, only 9 of 20 metastatic lesions (45%) were pigmented with high melanin content. 123I-BZA2 imaging was positive for 6 of 8 melanin-positive lesions, fairly positive for 3 of 10 melanin-negative lesions, and negative for 7 of 10 melanin-negative lesions. The sensitivity and specificity of 123I-BZA2 for the diagnosis of melanin-positive lesions were 75% and 70%, respectively. Because of a low 123I-BZA2 sensitivity, this clinical trial was prematurely closed after 87 patients had been included. Conclusion: This study confirms the value of 18F-FDG PET/CT for melanoma staging and strengthens the high accuracy of 123I-BZA2 for diagnosis of melanin-positive metastatic melanoma. Moreover, benzamide derivatives radiolabeled with therapeutic radionuclide may offer a new strategy for the treatment of metastatic melanoma patients harboring melanin-positive metastases.