TY - JOUR T1 - Quantitative and Qualitative Intrapatient Comparison of <sup>68</sup>Ga-DOTATOC and <sup>68</sup>Ga-DOTATATE: Net Uptake Rate for Accurate Quantification JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 204 LP - 210 DO - 10.2967/jnumed.113.126177 VL - 55 IS - 2 AU - Irina Velikyan AU - Anders Sundin AU - Jens Sörensen AU - Mark Lubberink AU - Mattias Sandström AU - Ulrike Garske-Román AU - Hans Lundqvist AU - Dan Granberg AU - Barbro Eriksson Y1 - 2014/02/01 UR - http://jnm.snmjournals.org/content/55/2/204.abstract N2 - Quantitative imaging and dosimetry are crucial for individualized treatment during peptide receptor radionuclide therapy (PRRT). 177Lu-DOTATATE and 68Ga-DOTATOC/68Ga-DOTATATE are used, respectively, for PRRT and PET examinations targeting somatostatin receptors (SSTRs) in patients affected by neuroendocrine tumors. The aim of the study was to quantitatively and qualitatively compare the performance of 68Ga-DOTATOC and 68Ga-DOTATATE in the context of subsequent PRRT with 177Lu-DOTATATE under standardized conditions in the same patient as well as to investigate the sufficiency of standardized uptake value (SUV) for estimation of SSTR expression. Methods: Ten patients with metastatic neuroendocrine tumors underwent one 45-min dynamic and 3 whole-body PET/CT examinations at 1, 2, and 3 h after injection with both tracers. The number of detected lesions, SUVs in lesions and normal tissue, total functional tumor volume, and SSTR volume (functional tumor volume multiplied by mean SUV) were investigated for each time point. Net uptake rate (Ki) was calculated according to the Patlak method for 3 tumors per patient. Results: There were no significant differences in lesion count, lesion SUV, Ki, functional tumor volume, or SSTR volume between 68Ga-DOTATOC and 68Ga-DOTATATE at any time point. The detection rate was similar, although with differences for single lesions in occasional patients. For healthy organs, marginally higher uptake of 68Ga-DOTATATE was observed in kidneys, bone marrow, and liver at 1 h. 68Ga-DOTATOC uptake was higher in mediastinal blood pool at the 1-h time point (P = 0.018). The tumor-to-liver ratio was marginally higher for 68Ga-DOTATOC at the 3-h time point (P = 0.037). Blood clearance was fast and similar for both tracers. SUV did not correlate with Ki linearly and achieved saturation for a Ki of greater than 0.2 mL/cm3/min, corresponding to an SUV of more than 25. Conclusion: 68Ga-DOTATOC and 68Ga-DOTATATE are suited equally well for staging and patient selection for PRRT with 177Lu-DOTATATE. However, the slight difference in the healthy organ distribution and excretion may render 68Ga-DOTATATE preferable. SUV did not correlate linearly with Ki and thus may not reflect the SSTR density accurately at its higher values, whereas Ki might be the outcome measure of choice for quantification of SSTR density and assessment of treatment outcome. ER -