TY - JOUR T1 - <sup>18</sup>F-ICMT-11, a Caspase-3–Specific PET Tracer for Apoptosis: Biodistribution and Radiation Dosimetry JF - Journal of Nuclear Medicine JO - J Nucl Med SP - 1551 LP - 1556 DO - 10.2967/jnumed.112.118760 VL - 54 IS - 9 AU - Amarnath Challapalli AU - Laura M. Kenny AU - William A. Hallett AU - Kasia Kozlowski AU - Giampaolo Tomasi AU - Mihir Gudi AU - Adil Al-Nahhas AU - R. Charles Coombes AU - Eric O. Aboagye Y1 - 2013/09/01 UR - http://jnm.snmjournals.org/content/54/9/1551.abstract N2 - Effective anticancer therapy induces tumor cell death through apoptosis. Noninvasive monitoring of apoptosis during therapy may provide predictive outcome information and help tailor treatment. A caspase-3–specific imaging radiotracer, 18F-(S)-1-((1-(2-fluoroethyl)-1H-[1,2,3]-triazol-4-yl)methyl)-5-(2(2,4-difluorophenoxymethyl)-pyrrolidine-1-sulfonyl)isatin (18F-ICMT-11), has been developed for use in PET studies. We report the safety, biodistribution, and internal radiation dosimetry profiles of 18F-ICMT-11 in 8 healthy human volunteers. Methods: 18F-ICMT-11 was intravenously administered as a bolus injection (mean ± SD, 159 ± 2.75 MBq; range, 154–161 MBq) to 8 healthy volunteers (4 men, 4 women). Whole-body (vertex to mid thigh) PET/CT scans were acquired at 6 time points, up to 4 h after tracer injection. Serial whole blood, plasma, and urine samples were collected for radioactivity measurement and radiotracer stability. In vivo 18F activities were determined from quantitative analysis of the images, and time–activity curves were generated. The total numbers of disintegrations in each organ normalized to injected activity (residence times) were calculated as the area under the curve of the time–activity curve, normalized to injected activities and standard values of organ volumes. Dosimetry calculations were then performed using OLINDA/EXM 1.1. Results: Injection of 18F-ICMT-11 was well tolerated in all subjects, with no serious tracer-related adverse events reported. The mean effective dose averaged over both men and women was estimated to be 0.025 ± 0.004 mSv/MBq (men, 0.022 ± 0.004 mSv/MBq; women, 0.027 ± 0.004 mSv/MBq). The 5 organs receiving the highest absorbed dose (mGy/MBq), averaged over both men and women, were the gallbladder wall (0.59 ± 0.44), small intestine (0.12 ± 0.05), upper large intestinal wall (0.08 ± 0.07), urinary bladder wall (0.08 ± 0.02), and liver (0.07 ± 0.01). Elimination was both renal and via the hepatobiliary system. Conclusion: 18F-ICMT-11 is a safe PET tracer with a dosimetry profile comparable to other common 18F PET tracers. These data support the further development of 18F-ICMT-11 for clinical imaging of apoptosis. ER -