PT - JOURNAL ARTICLE AU - Gerhard Ulrich AU - Oliver Dudeck AU - Christian Furth AU - Juri Ruf AU - Oliver S. Grosser AU - Daniela Adolf AU - Marvin Stiebler AU - Jens Ricke AU - Holger Amthauer TI - Predictive Value of Intratumoral <sup>99m</sup>Tc-Macroaggregated Albumin Uptake in Patients with Colorectal Liver Metastases Scheduled for Radioembolization with <sup>90</sup>Y-Microspheres AID - 10.2967/jnumed.112.112508 DP - 2013 Apr 01 TA - Journal of Nuclear Medicine PG - 516--522 VI - 54 IP - 4 4099 - http://jnm.snmjournals.org/content/54/4/516.short 4100 - http://jnm.snmjournals.org/content/54/4/516.full SO - J Nucl Med2013 Apr 01; 54 AB - 90Y radioembolization is a promising therapy for patients with primary and secondary liver malignancies. Pretherapeutic assessment consists of hepatic angiography and 99mTc-macroaggregated albumin (99mTc-MAA) perfusion scintigraphy to estimate the liver-to-lung shunt and exclude extrahepatic 99mTc-MAA deposition. However, the predictive value of intratumoral 99mTc-MAA uptake remains unclear. Methods: One hundred four patients with chemotherapy-refractory liver-dominant metastatic colorectal cancer were treated with 90Y radioembolization between December 2006 and December 2010. All of the patients underwent angiographic assessment and perfusion scintigraphy with 99mTc-MAA before lobar 90Y radioembolization. For inclusion, patients must have undergone pretherapeutic and follow-up MR imaging (6 wk and 3 mo after radioembolization, respectively). The degree of intratumoral 99mTc-MAA uptake was rated, and liver metastases were classified according to changes in tumor diameter on both an individual and a patient basis using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1. Response at both time points, MAA uptake, and catheter position were then statistically analyzed in a linear and generalized linear mixed model at a significance level of 0.05 (P value). Results: Sixty-six patients with a total of 435 colorectal liver metastases (mean number of lesions ± SD, 6.6 ± 2.8; mean lesion size ± SD, 33.8 ± 21.2 mm; lesion size range, 10–154 mm) were included in this analysis. According to the patient-based analysis, 3 patients had partial response, 49 stable disease, and 6 progressive disease after 6 wk. After 3 mo, 5 patients showed partial response, 26 stable disease, and 17 progressive disease. There was no association of patient-based tumor response with overall 99mTc-MAA uptake (P = 0.172) or with catheter position (P = 0.6456). Furthermore, an interaction effect of 99mTc-MAA uptake and catheter position in relation to tumor response was not found (P = 0.512). Moreover, in lesion-based analysis according to RECIST 1.1 there was no association of tumor response with degree of 99mTc-MAA uptake, catheter position, or interaction of 99mTc-MAA uptake and catheter position (P = 0.339, 0.593, and 0.658, respectively). Conclusion: Response to 90Y radioembolization was found to be independent of the degree of 99mTc-MAA uptake. Therefore, therapy should not be withheld from patients with colorectal liver metastases lacking intratumoral 99mTc-MAA accumulation.